DAMPAK MEDAN MAGNET PEMBANGUNAN JARINGAN LISTRIK PLTA LUTEUNG 16 MW TERHADAP KESEHATAN MASYARAKAT

Authors

  • Mahdi Syukri Jurusan Teknik Elektro dan Komputer, Fakultas Teknik, Universitas Syiah Kuala, Banda Aceh, Indonesia
  • Syukriyadin Syukriyadin 4Jurusan Teknik Elektro dan Komputer, Fakultas Teknik, Universitas Syiah Kuala, Banda Aceh, Indonesia
  • Alfisyahrin Alfisyahrin Jurusan Teknik Elektro dan Komputer, Fakultas Teknik, Universitas Syiah Kuala, Banda Aceh, Indonesia
  • Ramdhan Halid Siregar Jurusan Teknik Elektro dan Komputer, Fakultas Teknik, Universitas Syiah Kuala, Banda Aceh, Indonesia
  • Iqbar Iqbar Jurusan Biologi, Fakultas MIPA, Universitas Syiah Kuala, Banda Aceh, Indonesia

DOI:

https://doi.org/10.37249/jpma.v3i2.693

Keywords:

SUTT, SUTM, Dampak, Medan Magnet

Abstract

Salah satu tulang punggung penyaluran energi listrik dari pusat pembangkit ke beban adalah jaringan listrik saluran udara tegangan tinggi (SUTT) dan saluran udara tegangan menengah (SUTM). Pembangunan jaringan listrik SUTT dan SUTM tidak luput dari dampak yang ditimbulkan kepada masyarakat akibat adanya paparan medan magnet yang ditimbulkan pada jaringan. Keberadaan pembangunan jaringan SUTT dan SUTM yang menghubungkan jaringan tersebut ke pembangkit listrik tenaga air PLTA Luteung 16 MW menimbulkan kekhawatiran dampak kesehatan kepada masyarakat. Oleh karena itu pelaksanaan pengabdian ini bertujuan untuk melihat potensi medan magnet yang ditimbulkan jaringan SUTT dan SUTM yang melintas di desa Luteung. Dari hasil pengukuran dibawah jaringan SUTT pada koordinat N 04o 52’ 02.49” dan E 96o 05’ 06.15” diperoleh kuat medan magnet sebesar 1.57 ?T dan jaringan SUTM pada koordinat N 04o 52’14.77” dan E 96o 05’ 11.34” diperoleh kuat medan magnet sebesar 0 ?T. Berdasarkan Standar Nasional Indonesia SNI 04-6950-2003 dapat disimpulkan kuat medan magnet yang terukur masih dibawah ambang batas 25 mT sehingga dapat dinyatakan bahwa medan  magnet yang ditimbulkan  pada SUTT dan SUTM yang melintas di desa Luteung masih dalam taraf aman bagi kesehatan masyarakat Luteung.

References

Ala, G., Favuzza, S., Francomano, E., Giglia, G., & Zizzo, G. (2018). On the distribution of lightning current among interconnected grounding systems in medium voltage grids. Energies, 11(4), 771.

https:// doi.org/10.3390/en11040771

Anonymous. (2003). Saluran Udara Tegangan Tinggi (SUTT) dan Saluran Udara Tegangan Ekstra Tinggi (SUTET) - Nilai ambang batas medan listrik dan medan magnet, SNI Nomor 04-6950-2003.

Retrieved November 9, 2023, from https://pesta.bsn.go.id/produk/detail/6617-sni04-6950-2003

Cerretti, A., Gatta, F. M., Geri, A., Lauria, S., Maccioni, M., & Valtorta, G. (2012). Ground fault temporary overvoltages in MV networks: Evaluation and experimental tests. IEEE Transactions on Power Delivery, 27(3), 1592-1600.

https://doi.org/10.1109/tpwrd.2012.2192456

Chudnovsky, B. H. (2012). Electrical power transmission and distribution: aging and life extension techniques. CRC Press.

Draper, G., Vincent, T., Kroll, M. E., & Swanson, J. (2005). Childhood cancer in relation to distance from high voltage power lines in England and Wales: a case-control study. Bmj, 330(7503), 1290.

https://doi.org/10.1136/bmj.330.7503.1290

Elgayar, A., Abdul-Malek, Z., Othman, R., Elshami, I. F., Elbreki, A. M., Ibrahim, V. M., Mousa, M.I., & Wooi, C. L. (2019). Power transmission lines electromagnetic pollution with consideration of soil resistivity. TELKOMNIKA (Telecommunication Computing Electronics and Control), 17(4), 1985-1991.

https://doi.org/10.12928/telkomnika.v17i4.12771

De Franco, J. L., & Fillho. J.P. (2011). Improvement of the transmission and sub-transmission overhead lines lightning performance using line arresters–Experience in Brazil. Journal of Energy: Energija, 60(1-4), 61-68.

https://doi.org/10.37798/2011601-4263

Hemami, A. (2017). Electricity and Electronics for Renewable Energy Technology: An Introduction. CRC Press.

Homma, A. (2011). High-voltage isolation transformer for sub-nanosecond rise time pulses constructed with annular parallel-strip transmission lines. Review of Scientific Instruments, 82(7).

https://doi.org/10.1063/1.3606448

Siero?-Sto?tny, K., Pasek, J., Cie?lar, G., & Siero?, A. (2017). Influence of Electromagnetic Fields on Prooxidant/Antioxidant Balance in Rat Liver. Polish Journal of Environmental Studies, 26(1), 279-285.

https://doi.org/10.15244/pjoes/64747

Uwiringiyimana, J. P., Khayam, U., & Montanari, G. C. (2022). Design and implementation of ultra-wideband antenna for partial discharge detection in high voltage power equipment. IEEE Access, 10, 10983-10994.

https://doi.org/10.1109/access.2022.3144416

Downloads

Published

2023-12-18

How to Cite

Syukri, M., Syukriyadin, S., Alfisyahrin, A., Siregar, R. H., & Iqbar, I. (2023). DAMPAK MEDAN MAGNET PEMBANGUNAN JARINGAN LISTRIK PLTA LUTEUNG 16 MW TERHADAP KESEHATAN MASYARAKAT. JPMA - Jurnal Pengabdian Masyarakat As-Salam, 3(2), 57–62. https://doi.org/10.37249/jpma.v3i2.693